1 Core

Cu/PVC (NYA) - 450/750 VOLT

IEC 60227.3/SNI 04-6629.3

  • Manufacturing Specification
  • Single Core, Copper Conductor and PVC Insulated Cable
  • Main Uses:
  • Used for grounding cable or internal wiring in dry location

1 Core Solid

Cu/PVC/PVC (NYY) 0.6/1(1.2) kV

IEC 60502-1/ SNI IEC 60502-1

  • Manufacturing Specification
  • Copper conductor, PVC insulated and PVC sheathed
  • Main Uses:
  • used for indoor, in ducts installation for laying in the ground, where not sustain mechanical damage

2 Core

  • Cu/PVC/PVC (NYY) 0.6/1(1.2) kV
  • IEC 60502-1/ SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated and PVC sheathed cable
    • Main Uses:
    • used for indoor, in ducts installation for laying in the ground, where not sustain mechanical damage

    Cu/PVC/AWA/PVC (NYRY) 0.6/1 kV

    IEC 60502-1 / SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated, Aluminium wire armoured and PVC sheathed cable
    • Main Uses:
    • used for indoor and outdoor installation direct burial, preferably used where considerable mechanical strees must be envisaged

    2 Core

  • Cu/PVC/SWA/PVC (NYRGbY)
  • 0.6/1(1.2) kV
  • IEC 60502-1 / SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated, Galvanized round steel
    • Main Uses:
    • used for indoor and outdoor installation direct burial, preferably used where considerable mechanical strees must be envisaged

    2 Core

  • Cu/PVC/SWA/PVC (NYFGbY)
  • 0.6/1(1.2) kV
  • IEC 60502-1 / SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated, Galvanized round steel
    • Main Uses:
    • used for indoor and outdoor installation direct burial, preferably used where considerable mechanical strees must be envisaged

    1 Core

    Cu/PVC/CTS/PVC (NYSY) 0.6/1(1.2) kV

    IEC 60502-1/ SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated, copper tape screened and PVC sheathed cable
    • Main Uses:
    • used for indoor, in ducts installation for laying in the ground, where not sustain mechanical damage and need for electrical screen

    1 Core

    Cu/PVC/CWS/PVC (NYCY) 0.6/1(1.2) kV

    IEC 60502-1/ SNI IEC 60502-1

    • Manufacturing Specification
    • Copper conductor, PVC insulated, copper wire screened and PVC sheathed cable
    • Main Uses:
    • used for indoor, in ducts installation for laying in the ground, where not sustain mechanical damage and need for electrical screen